Proof W3 lane T2: effects engine and colour fan (2026-10-11)

Period at 120 BPM, beats 2 (target 1000 ms within 2 %)

Measure Result
Sine-fit period, all 12 fixtures 1000.0 ms each (min 1000.0, max 1000.0), error 0.0 %
Zero crossings, 2201, 7 intervals mean 1000.0 ms, min 999.9, max 1000.2
Range on every fixture 0 to 255

Spread 50 (expected lag i x 0.5/12 cycle = 41.67 ms per place)

Place Fixture Lag measured Expected Error
0 2201 0.0 ms 0.0 0.0
1 3101 41.7 41.7 0.0
2 2206 83.3 83.3 0.0
3 2202 125.0 125.0 0.0
4 3102 166.7 166.7 0.0
5 2203 208.3 208.3 0.0
6 3103 250.0 250.0 0.0
7 2204 291.7 291.7 0.0
8 3104 333.3 333.3 0.0
9 2207 375.0 375.0 0.0
10 2205 416.7 416.7 0.0
11 3105 458.3 458.3 0.0

Continuity: BPM change and live edits

Metric: the largest change on any of the 12 dimmers between a sample and the sample 25 ms (one frame) later. It is taken around the moment of the change, and compared with the same metric in steady running on either side. The steady figure measures 18 to 48 counts, against a theoretical 20 at 1 Hz, because the sample times carry up to 21 ms of request jitter. That steady figure is the frame step the change is held to.

Change Steady before Across the change Steady after Result
BPM 120 to 90, trial 1 34 42 36 within steady range of the run (max 48)
BPM 120 to 90, trial 2 36 21 41 pass
BPM 120 to 90, trial 3 48 21 27 pass
beats 2 to 1 at 90 BPM, 3 trials 38 / 38 / 19 31 / 31 / 31 78 / 51 / 54 (faster wave) pass
spread 50 to 0 18 35 n/a pass

Grand master 50 halves the peak

Peak, all 12 Trough, all 12
Master 100 255 0
Master 50 127 0

The worst ratio error was 0.002 (127/255 = 0.498).

Blackouts and undo

Mood recall drops only the lights it writes

Look Writes dimmer on Effect fixtures after the recall Expected
763 RED ALARM 2201 to 2207 3101 to 3105 3101 to 3105
771 SLOW PULSE 2201 to 2207 3101 to 3105 3101 to 3105

Hit above the effect

The effect was a sine on the 12 pars at base 100. The test pressed hit seldip (BLACKOUT HIT) on 2201 and 2202. - While it was held, 2201 and 2202 read a maximum of 0. 3101 kept swinging 0 to 255. - After release, 2201 swung 0 to 255 again and the effect was still running.

Colour fan, from h 0 to h 240 (s 100, l 50) across the 12 pars

This is POST /api/colour/fan {fixtures:[12 pars], from:{h:0,s:100,l:50}, to:{h:240,s:100,l:50}}. The pars were at full on groups 3 and 5. The hue is read from the frame's ColorRGB_R/G/B channels.

Fixture Map x Asked hue Frame RGB Frame hue
2201 -3.2 0 255, 0, 0 0.0
3101 -3.2 21.8 255, 93, 0 21.9
2206 -2.5 43.6 255, 186, 0 43.8
2202 -1.6 65.5 232, 255, 0 65.4
3102 -1.6 87.3 139, 255, 0 87.3
2203 0 109.1 46, 255, 0 109.2
3103 0 130.9 0, 255, 46 130.8
2204 1.6 152.7 0, 255, 139 152.7
3104 1.6 174.5 0, 255, 232 174.6
2207 2.5 196.4 0, 186, 255 196.2
2205 3.2 218.2 0, 93, 255 218.1
3105 3.2 240 0, 0, 255 240.0

Regression

tools/regress-v2.sh 7093 gave GREEN, 14 passed. The checks were status, pick, aim, stack, mood-solo, hit, blackout, undo, timeline, userscene, /desk.html, /screen2.html, phone and /help/.